4. Power and Connection
4.1 External Power System Design Guide
-
Voltage range requirements
Odin1 Lite’s nominal operating voltage is DC 9–24 V. It is recommended to use a 12 V / 2 A DC adapter (≥ 24 W power margin); otherwise, the device may fail to start or work unstably due to insufficient instantaneous current.
-
Power adapter notes
- Connect the adapter through the DC jack of the power-and-data splitter aviation cable; the DC jack specification is 5.5×2.1 mm.
- Odin1 Lite does not include a power adapter by default; users must prepare a compliant 12 V adapter.
-
Voltage surge protection warning
⚠️ Voltage fluctuations exceeding the rated upper limit on the power line may cause permanent damage to the device. It is recommended to add overvoltage protection circuitry in the power loop.
-
Power consumption characteristics
Operating State Power Characteristics Stable operation Typical ≈ 11 W Cold-start peak Maximum 24 W -
Key power selection parameters
- Continuous output capability ≥ 2 A
- Recommended power margin ≥ 24 W
- Recommended overvoltage protection threshold ≤ 26 V
4.2 Connection Steps
Odin1 Lite communicates with the PC via Ethernet.
- Insert the aviation plug of the power-and-data splitter aviation cable into the Odin1 Lite interface in the correct groove direction, and tighten the threaded ring.
- Connect the DC jack to the 12 V / 2 A adapter and power on; the device indicator staying on means power-on success.
- Connect the RJ45 network cable to the PC Ethernet port (or switch).
- Configure the PC Ethernet card IP to
192.168.1.x/24(same subnet as the device192.168.1.251). - After confirming communication is normal with
ping 192.168.1.251, you can start the driver or access the HTTP Dashboard.
🔧 For detailed network configuration steps, see 7. Odin1 Lite Quick Start (Ubuntu) §7.2.3 Network Configuration.
← Previous Chapter:Installation Guide | Next Chapter:Data Output →